News:


  • April 27, 2024, 02:26:53 AM

Login with username, password and session length

Author Topic: ? Rib thickness  (Read 1011 times)

Offline John Crocker

  • Trade Count: (0)
  • Commander
  • ****
  • Posts: 222
? Rib thickness
« on: July 01, 2007, 06:12:09 PM »
Okay, I'm hooked again.  Got back into this mess about 2 months ago after being gone for 25 yrs.  Did a couple of sheet wings for my boy and I and the first one met a greasy ending yesterday in some wind that I should not have been flying in.

So heres my question.  Going to put together another scratch built with a built up wing (something easy like a baby clown knock off), but have no idea on the rib thickness.  I'm thinking 1/8" balsa, will that be enough?  Going to build the body out of 1/4" balsa and beam mount a norvel .049 with a 1 oz clunk tank.

Also, whats the best thing to cover with now.  Monokote was just coming on strong (never used it)when I got out of models and I know there are several other items out there now.  I always used tissue, silk or lightweight nylon (which I have in spades at work).  Thoughts?

Offline Roger Vizioli

  • CLiner
  • 21 supporter
  • Trade Count: (0)
  • Admiral
  • *
  • Posts: 1171
Re: ? Rib thickness
« Reply #1 on: July 01, 2007, 06:20:20 PM »
I use 1/16" th. rib material on 1/2A's.
you can add 1/8" sq. spars and LE and TE of your liking.
R....
Roger Vizioli
AMA L-2408
Florida/Space Coast

Offline Clancy Arnold

  • 2015
  • Trade Count: (0)
  • Admiral
  • *
  • Posts: 1453
  • I am 5 Ft. 8 In., the Taube is 7 Ft. 4 In.
Re: ? Rib thickness
« Reply #2 on: July 01, 2007, 06:30:56 PM »
John
When I built my set of Barnstormers I used 1/8 for the fox 35 powered full size, 1/16 for the WenMac .049 powered Baby Barnstormer, 1/20 for the Cox .020 powered IBTW Barnstormer and 1/32 for the Cox .010 Micro Barnstormer.

Hope this helps.

Clancy
Clancy Arnold
Indianapolis, IN   AMA 12560 LM-S
U/Tronics Control
U/Control with electronics added.

Offline LARRY RICE

  • 2014 Supporters
  • Trade Count: (0)
  • Admiral
  • *
  • Posts: 1291
Re: ? Rib thickness
« Reply #3 on: July 01, 2007, 07:24:19 PM »
John,
     Our new line of 1/2a control line kits with build up wings use 1/16th inch thick ribs in a 28 inch wing span and 6 inch chord. The fuselage is 1/4 inch by 2 inch by 23 inches. That's it.
Larry

Offline minnesotamodeler

  • 2014 Supporters
  • Trade Count: (0)
  • Admiral
  • *
  • Posts: 2335
  • Me and my Chief Engineer
    • Minnesotamodeler
Re: ? Rib thickness
« Reply #4 on: July 01, 2007, 07:28:48 PM »
1/16" ribs are fine, use spars top and bottom (1/8"x1/4"? 3/32"x3/16"?).  Be sure to put 1/4" square hardwood beams at the motor mount, with thin plywood (1/32" is enough) doublers.

--Ray

P.S. Covering, no-one's addressed that yet--I've been using "microlite" by Coverite, an iron-on film like Monocote that is very thin and light, perfect for 1/2A.  Silkspan and dope are still used a lot.
--Ray 
Roseville MN (St. Paul suburb, Arctic Circle)
AMA902472


Advertise Here
Tags:
 


Advertise Here